IP Class Rating (International Protection)

First Code Number*
I P * *
Classifies Protection against Touch and Intrusion of Foreign Particles
|
Code
|
Description |
Level of Protection |
|
0
|
No Protection |
No protection against accidental touch of parts under power or moving or stationary parts. |
|
1
|
Protection against large foreign parts |
Protection against accidental touch of parts under power in large areas or internal moving parts. Protected against intrusion of particles larger than 50mm diameter |
|
2
|
Protection against medium foreign particles |
Protection against accidental touch with fingers of parts under power or moving internal parts. Protected against intrusion of particles larger than 12mm diameter. |
|
3
|
Protection against small foreign particles |
Protection against accidental touch of parts under power or internal moving part with tools, wires or similar objects with thickness of larger than 2.5mm. Protected against intrusion of particles larger than 1mm. |
|
4
|
Protection against grain-sized particles |
Protection against accidental touch of parts under power or internal moving parts with tools, wires, or similar objects with a size larger than 1mm. Protected against intrusion of parts larger than 1mm. |
|
5
|
Protection against dust deposit |
Complete protection against accidental touch of parts under power or internal moving parts with tools, wires, or similar objects. Protected against intrusion of dust particles is not completely prevented, but dust particles can not deposit in such quantity that performance is compromised. |
|
6
|
Protection against intrusion |
Complete protection against accidental touch of parts under power or internal moving parts. Protected against detrimental dust deposition. Intrusion of dust is not completely prevented, but can not have a detrimental effect on the performance of the device. |

Second Code Number*
I P * *
Classifies Protection against Intrusion of Water
|
Code
|
Description |
Level of Protection |
|
0
|
No Protection |
No designated protection. |
|
1
|
Protection against vertical water droplets |
Water droplets falling vertically onto the device have not negative effect. |
|
2
|
Protection against oblique falling droplets |
Water droplets falling at an angle of not more than 15° from the vertical onto the device have no negative effect. |
|
3
|
Protection against water splash |
Water, falling at an angle of no more than 60° from vertical have no negative effect on the device. |
|
4
|
Protection against water spray |
Protection against water spray |
|
5
|
Protection against water jet |
Water jet from all directions has no measurable negative effect. |
|
6
|
Protection against flooding |
Water has no negative effect during temporarily flooding. |
|
7
|
Protection against submersion |
Water can not penetrate for a defined period and depth of submersion. |
|
8
|
Protection while permanently submersed |
Water can not penetrate for an indefinite period of submersion at a defined depth. |

Return to main Technical Information page
|